{"title":"Gas Detection \u0026 Multi-Gas Monitors","description":"\u003cp\u003eThis gas detection collection is mostly made up of Gastec detector tubes, sold in boxes of 10, for hydrogen sulfide (H2S) and carbon monoxide (CO), with different measuring ranges. It also includes a few MSA gas detection items.\u003c\/p\u003e\u003cp\u003eThese products are supplied B2B to Senegal and Canada for industry and maintenance. Request a quote for your bulk orders.\u003c\/p\u003e","products":[{"product_id":"gastec-h2s-detector-tube-no-4lt-0-05-4-ppm-box-of-10-4lt","title":"Gastec H2S Detector Tube No. 4LT, 0.05–4 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 4LT measures hydrogen sulfide (H2S) in air from 0.05 to 4 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from yellow to pink, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eHydrogen sulfide is a toxic gas found around oil and gas wells, sour gas lines, sewers, ballast and bilge tanks and other confined spaces. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures hydrogen sulfide (H2S) from 0.05 to 4 ppm\u003c\/li\u003e\u003cli\u003eColour change yellow to pink\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 24-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e4LT\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG4LT\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ehydrogen sulfide (H2S)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.05–4 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.05–0.1 ppm: 2 strokes (200 mL) in 3 min; 0.1–2.0 ppm: 1 stroke (100 mL) in 1.5 min; 2.0–4.0 ppm: ½ stroke (50 mL) in 45 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003eyellow to pink\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.01 ppm (2 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e24 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eStorage\u003c\/th\u003e\u003ctd\u003eIn a refrigerator, per the data sheet\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e4LT\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/4LT.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/4LT.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/4LT.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568120299734,"sku":"BP-L-IG4LT","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/4lt.jpg?v=1791600422"},{"product_id":"gastec-h2s-detector-tube-no-4lb-0-5-12-ppm-box-of-10-4lb","title":"Gastec H2S Detector Tube No. 4LB, 0.5–12 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 4LB measures hydrogen sulfide (H2S) in air from 0.5 to 12 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from yellow to pink, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eHydrogen sulfide is a toxic gas found around oil and gas wells, sour gas lines, sewers, ballast and bilge tanks and other confined spaces. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures hydrogen sulfide (H2S) from 0.5 to 12 ppm\u003c\/li\u003e\u003cli\u003eColour change yellow to pink\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 24-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e4LB\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG4LB\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ehydrogen sulfide (H2S)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.5–12 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.5–1 ppm: 2 strokes (200 mL) in 2 min; 1–6 ppm: 1 stroke (100 mL) in 1 min; 6–12 ppm: ½ stroke (50 mL) in 30 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003eyellow to pink\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.07 ppm (2 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e24 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e4LB\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/4LB.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/4LB.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/4LB.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568120332502,"sku":"BP-L-IG4LB","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/4lb.jpg?v=1791600423"},{"product_id":"gastec-h2s-detector-tube-no-4ll-0-25-120-ppm-box-of-10-4ll","title":"Gastec H2S Detector Tube No. 4LL, 0.25–120 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 4LL measures hydrogen sulfide (H2S) in air from 0.25 to 120 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from white to brown, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eHydrogen sulfide is a toxic gas found around oil and gas wells, sour gas lines, sewers, ballast and bilge tanks and other confined spaces. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures hydrogen sulfide (H2S) from 0.25 to 120 ppm\u003c\/li\u003e\u003cli\u003eColour change white to brown\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e4LL\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG4LL\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ehydrogen sulfide (H2S)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.25–120 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.25–2.5 ppm: 2 to 10 strokes (200–1000 mL) in 2 to 10 min; 2.5–60 ppm: 1 stroke (100 mL) in 1 min; 60–120 ppm: ½ stroke (50 mL) in 30 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ewhite to brown\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.1 ppm (10 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e4LL\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDisposal note\u003c\/th\u003e\u003ctd\u003econtains 0.08 mg of lead per the SDS; dispose of per local regulations\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/4LL.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/4LL.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/4LL.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568120398038,"sku":"BP-L-IG4LL","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/4ll.jpg?v=1791600425"},{"product_id":"gastec-h2s-detector-tube-no-4l-1-240-ppm-box-of-10-4l","title":"Gastec H2S Detector Tube No. 4L, 1–240 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 4L measures hydrogen sulfide (H2S) in air from 1 to 240 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from white to brown, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eHydrogen sulfide is a toxic gas found around oil and gas wells, sour gas lines, sewers, ballast and bilge tanks and other confined spaces. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures hydrogen sulfide (H2S) from 1 to 240 ppm\u003c\/li\u003e\u003cli\u003eColour change white to brown\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e4L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG4L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ehydrogen sulfide (H2S)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e1–240 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e1–10 ppm: 2 to 10 strokes (200–1000 mL) in 1.5 to 7.5 min; 10–120 ppm: 1 stroke (100 mL) in 45 s; 120–240 ppm: ½ stroke (50 mL) in 30 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ewhite to brown\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.2 ppm (10 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e4L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDisposal note\u003c\/th\u003e\u003ctd\u003econtains 0.17 mg of lead per the SDS; dispose of per local regulations\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/4L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/4L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/4L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568121118934,"sku":"BP-L-IG4L","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/4l.jpg?v=1791600490"},{"product_id":"gastec-h2s-detector-tube-no-4m-12-5-500-ppm-box-of-10-4m","title":"Gastec H2S Detector Tube No. 4M, 12.5–500 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 4M measures hydrogen sulfide (H2S) in air from 12.5 to 500 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from white to brown, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eHydrogen sulfide is a toxic gas found around oil and gas wells, sour gas lines, sewers, ballast and bilge tanks and other confined spaces. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures hydrogen sulfide (H2S) from 12.5 to 500 ppm\u003c\/li\u003e\u003cli\u003eColour change white to brown\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e4M\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG4M\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ehydrogen sulfide (H2S)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e12.5–500 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e12.5–25 ppm: 2 strokes (200 mL) in 1.5 min; 25–250 ppm: 1 stroke (100 mL) in 45 s; 250–500 ppm: ½ stroke (50 mL) in 30 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ewhite to brown\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e2.5 ppm (2 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e4M\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDisposal note\u003c\/th\u003e\u003ctd\u003econtains 0.38 mg of lead per the SDS; dispose of per local regulations\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/4M.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/4M.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/4M.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568121184470,"sku":"BP-L-IG4M","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/4m.jpg?v=1791600491"},{"product_id":"gastec-h2s-detector-tube-no-4h-10-4000-ppm-box-of-10-4h","title":"Gastec H2S Detector Tube No. 4H, 10–4000 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 4H measures hydrogen sulfide (H2S) in air from 10 to 4000 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from white to brown, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eHydrogen sulfide is a toxic gas found around oil and gas wells, sour gas lines, sewers, ballast and bilge tanks and other confined spaces. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures hydrogen sulfide (H2S) from 10 to 4000 ppm\u003c\/li\u003e\u003cli\u003eColour change white to brown\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e4H\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG4H\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ehydrogen sulfide (H2S)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e10–4000 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e10–100 ppm: 2 to 10 strokes (200–1000 mL) in 1.5 to 7.5 min; 100–2000 ppm: 1 stroke (100 mL) in 45 s; 2000–4000 ppm: ½ stroke (50 mL) in 30 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ewhite to brown\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e2 ppm (10 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e4H\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDisposal note\u003c\/th\u003e\u003ctd\u003econtains 2.70 mg of lead per the SDS; dispose of per local regulations\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/4H.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/4H.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/4H.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568121544918,"sku":"BP-L-IG4H","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/4h.jpg?v=1791600492"},{"product_id":"gastec-h2s-detector-tube-no-4hm-25-1600-ppm-box-of-10-4hm","title":"Gastec H2S Detector Tube No. 4HM, 25–1600 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 4HM measures hydrogen sulfide (H2S) in air from 25 to 1600 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from white to brown, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eHydrogen sulfide is a toxic gas found around oil and gas wells, sour gas lines, sewers, ballast and bilge tanks and other confined spaces. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures hydrogen sulfide (H2S) from 25 to 1600 ppm\u003c\/li\u003e\u003cli\u003eColour change white to brown\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e4HM\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG4HM\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ehydrogen sulfide (H2S)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e25–1600 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e25–50 ppm: 2 strokes (200 mL) in 1.5 min; 50–800 ppm: 1 stroke (100 mL) in 45 s; 800–1600 ppm: ½ stroke (50 mL) in 30 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ewhite to brown\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e5 ppm (2 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e4HM\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDisposal note\u003c\/th\u003e\u003ctd\u003econtains 1.30 mg of lead per the SDS; dispose of per local regulations\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/4HM.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/4HM.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/4HM.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568122757334,"sku":"BP-L-IG4HM","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/4hm.jpg?v=1791600571"},{"product_id":"gastec-co-detector-tube-no-1l-2-5-2000-ppm-box-of-10-1l","title":"Gastec CO Detector Tube No. 1L, 2.5–2000 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 1L measures carbon monoxide (CO) in air from 2.5 to 2000 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from yellow to blackish brown, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eCarbon monoxide comes from engines, generators, heaters and welding or burning work in enclosed or poorly ventilated areas. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures carbon monoxide (CO) from 2.5 to 2000 ppm\u003c\/li\u003e\u003cli\u003eColour change yellow to blackish brown\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e1L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG1L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ecarbon monoxide (CO)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e2.5–2000 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e2.5–25 ppm: 2 to 10 strokes (200–1000 mL) in 2 to 10 min; 25–1000 ppm: 1 stroke (100 mL) in 1 min; 1000–2000 ppm: ½ stroke (50 mL) in 30 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003eyellow to blackish brown\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e1 ppm (10 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e1L\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/1L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/1L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/1L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568122790102,"sku":"BP-L-IG1L","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/1l.jpg?v=1791600572"},{"product_id":"gastec-co-detector-tube-no-1lk-5-600-ppm-box-of-10-1lk","title":"Gastec CO Detector Tube No. 1LK, 5–600 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 1LK measures carbon monoxide (CO) in air from 5 to 600 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from white to pale brown \/ pale green (dual layers), and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eCarbon monoxide comes from engines, generators, heaters and welding or burning work in enclosed or poorly ventilated areas. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures carbon monoxide (CO) from 5 to 600 ppm\u003c\/li\u003e\u003cli\u003eColour change white to pale brown \/ pale green (dual layers)\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e1LK\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG1LK\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ecarbon monoxide (CO)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e5–600 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e5–100 ppm: 3 strokes (300 mL) in 6 min; 100–300 ppm: 1 stroke (100 mL) in 2 min; 300–600 ppm: ½ stroke (50 mL) in 1 min\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ewhite to pale brown \/ pale green (dual layers)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.5 ppm (3 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e1LK\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDisposal note\u003c\/th\u003e\u003ctd\u003econtains 0.51 mg of selenium and 2.60 mg of hexavalent chromium per the SDS; dispose of per local regulations\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/1LK.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/1LK.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/1LK.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568122855638,"sku":"BP-L-IG1LK","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/1lk.jpg?v=1791600573"},{"product_id":"gastec-co2-detector-tube-no-2h-0-5-20-box-of-10-2h","title":"Gastec CO2 Detector Tube No. 2H, 0.5–20 %, Box of 10","description":"\u003cp\u003eGastec detector tube No. 2H measures carbon dioxide (CO2) in air from 0.5 to 20 %. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from white to purple, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eCarbon dioxide can build up in tanks, holds, pits and fermentation or dry-ice areas, where it displaces breathable air. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures carbon dioxide (CO2) from 0.5 to 20 %\u003c\/li\u003e\u003cli\u003eColour change white to purple\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e2H\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG2H\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ecarbon dioxide (CO2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.5–20 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.5–1 %: 2 strokes (200 mL) in 1.5 min; 1–10 %: 1 stroke (100 mL) in 45 s; 10–20 %: ½ stroke (50 mL) in 30 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ewhite to purple\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.1 % (2 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e2H\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/2H.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/2H.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/2H.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568123248854,"sku":"BP-L-IG2H","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/2h.jpg?v=1791600623"},{"product_id":"gastec-co2-detector-tube-no-2l-0-13-6-box-of-10-2l","title":"Gastec CO2 Detector Tube No. 2L, 0.13–6 %, Box of 10","description":"\u003cp\u003eGastec detector tube No. 2L measures carbon dioxide (CO2) in air from 0.13 to 6 %. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from white to purple, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eCarbon dioxide can build up in tanks, holds, pits and fermentation or dry-ice areas, where it displaces breathable air. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures carbon dioxide (CO2) from 0.13 to 6 %\u003c\/li\u003e\u003cli\u003eColour change white to purple\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e2L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG2L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ecarbon dioxide (CO2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.13–6 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.13–0.25 %: 2 strokes (200 mL) in 3 min; 0.25–3.0 %: 1 stroke (100 mL) in 1.5 min; 3.0–6.0 %: ½ stroke (50 mL) in 45 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ewhite to purple\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.025 % (2 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e2L\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/2L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/2L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/2L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568123281622,"sku":"BP-L-IG2L","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/2l.jpg?v=1791600625"},{"product_id":"gastec-so2-detector-tube-no-5lc-0-1-22-ppm-box-of-10-5lc","title":"Gastec SO2 Detector Tube No. 5LC, 0.1–22 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 5LC measures sulfur dioxide (SO2) in air from 0.1 to 22 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from bluish purple to white, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eSulfur dioxide is released when sulfur-bearing fuels and gases are burned, for example at flare stacks, boilers and engine exhaust. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures sulfur dioxide (SO2) from 0.1 to 22 ppm\u003c\/li\u003e\u003cli\u003eColour change bluish purple to white\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e5LC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG5LC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003esulfur dioxide (SO2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.1–22 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.1–0.25 ppm: 4 strokes (400 mL) in 8 min; 0.25–10 ppm: 2 strokes (200 mL) in 4 min; 10–22 ppm: 1 stroke (100 mL) in 2 min\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ebluish purple to white\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.02 ppm (4 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eRequired (see the instruction manual)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e5LC\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/5LC.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/5LC.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/5LC.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568123314390,"sku":"BP-L-IG5LC","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/5lc.jpg?v=1791600625"},{"product_id":"gastec-nh3-detector-tube-no-3l-0-5-78-ppm-box-of-10-3l","title":"Gastec NH3 Detector Tube No. 3L, 0.5–78 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 3L measures ammonia (NH3) in air from 0.5 to 78 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from pink to yellow, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eAmmonia is used as a refrigerant and in fertilizer and chemical processes, and leaks are a hazard in plants, cold stores and vessels. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures ammonia (NH3) from 0.5 to 78 ppm\u003c\/li\u003e\u003cli\u003eColour change pink to yellow\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e3L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG3L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003eammonia (NH3)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.5–78 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.5–1 ppm: 2 strokes (200 mL) in 1.5 min; 1–30 ppm: 1 stroke (100 mL) in 45 s; 30–78 ppm: ½ stroke (50 mL) in 30 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003epink to yellow\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.2 ppm (2 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eRequired (see the instruction manual)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e3L\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/3L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/3L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/3L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568123969750,"sku":"BP-L-IG3L","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/3l.jpg?v=1791600676"},{"product_id":"gastec-benzene-detector-tube-no-121-2-5-120-ppm-box-of-10-121","title":"Gastec Benzene Detector Tube No. 121, 2.5–120 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 121 measures benzene in air from 2.5 to 120 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from white to dark green, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eBenzene vapour is found around crude oil, gasoline and other petroleum products, for example during tank cleaning and sampling. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures benzene from 2.5 to 120 ppm\u003c\/li\u003e\u003cli\u003eColour change white to dark green\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e121\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG121\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ebenzene\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e2.5–120 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e2.5–5 ppm: 4 strokes (400 mL) in 6 min; 5–60 ppm: 2 strokes (200 mL) in 3 min; 60–120 ppm: 1 stroke (100 mL) in 1.5 min\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ewhite to dark green\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.5 ppm (4 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e121\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDisposal note\u003c\/th\u003e\u003ctd\u003econtains 0.78 mg of hexavalent chromium per the SDS; dispose of per local regulations\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/121.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/121.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/121.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568124002518,"sku":"BP-L-IG121","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/121.jpg?v=1791600677"},{"product_id":"gastec-o2-detector-tube-no-31b-3-24-box-of-5-31b","title":"Gastec O2 Detector Tube No. 31B, 3–24 %, Box of 5","description":"\u003cp\u003eGastec detector tube No. 31B measures oxygen (O2) in air from 3 to 24 %. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from black to white, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 5 tubes per box give 5 tests.\u003c\/p\u003e\u003cp\u003eOxygen level checks help find oxygen-deficient air in tanks, holds, vessels and other confined spaces before anyone enters. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures oxygen (O2) from 3 to 24 %\u003c\/li\u003e\u003cli\u003eColour change black to white\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e5 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e31B\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG31B\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003eoxygen (O2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e3–24 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e3–6 %: 1 stroke (100 mL) in 1 min; 6–24 %: ½ stroke (50 mL) in 30 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003eblack to white\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e2 % (1 stroke)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e5\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e31B\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/31B.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/31B.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/31B.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568124035286,"sku":"BP-L-IG31B","price":71950.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/31b.jpg?v=1791600678"},{"product_id":"gastec-lp-gas-detector-tube-no-100a-0-02-0-8-box-of-10-100a","title":"Gastec LP Gas Detector Tube No. 100A, 0.02–0.8 %, Box of 10","description":"\u003cp\u003eGastec detector tube No. 100A measures LP gas (propane and butane, C3–C4 hydrocarbons) in air from 0.02 to 0.8 %. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from yellowish brown to greenish brown, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eLP gas leaks can collect in low spots, engine rooms, galleys and storage areas, so a spot check is useful after a suspected leak. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures LP gas (propane and butane, C3–C4 hydrocarbons) from 0.02 to 0.8 %\u003c\/li\u003e\u003cli\u003eColour change yellowish brown to greenish brown\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e100A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG100A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003eLP gas (propane and butane, C3–C4 hydrocarbons)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.02–0.8 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.02–0.8 %: 1 stroke (100 mL) in 2 min\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003eyellowish brown to greenish brown\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.002 % (1 stroke)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eCalibration gas\u003c\/th\u003e\u003ctd\u003epropylene\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e100A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDisposal note\u003c\/th\u003e\u003ctd\u003econtains 5.30 mg of hexavalent chromium per the SDS; dispose of per local regulations\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/100A.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/100A.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/100A.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568125182166,"sku":"BP-L-IG100A","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/100a.jpg?v=1791600732"},{"product_id":"gastec-mercaptan-detector-tube-no-70-0-5-120-ppm-box-of-10-70","title":"Gastec Mercaptan Detector Tube No. 70, 0.5–120 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 70 measures mercaptans (RSH) in air from 0.5 to 120 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from white to yellow, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eMercaptans are the odorants added to natural gas and LP gas, and they are also released in refining and sour gas processing. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures mercaptans (RSH) from 0.5 to 120 ppm\u003c\/li\u003e\u003cli\u003eColour change white to yellow\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e70\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG70\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003emercaptans (RSH)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.5–120 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.5–5 ppm: 2 to 10 strokes (200–1000 mL) in 3 to 15 min; 5–120 ppm: 1 stroke (100 mL) in 1.5 min\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ewhite to yellow\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.2 ppm (10 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eRequired (see the instruction manual)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e70\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDisposal note\u003c\/th\u003e\u003ctd\u003econtains 0.91 mg of lead per the SDS; dispose of per local regulations\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/70.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/70.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/70.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568125214934,"sku":"BP-L-IG70","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/70.jpg?v=1791600733"},{"product_id":"gastec-water-vapor-detector-tube-no-6-0-5-32-mg-l-box-of-10-6","title":"Gastec Water Vapor Detector Tube No. 6, 0.5–32 mg\/L, Box of 10","description":"\u003cp\u003eGastec detector tube No. 6 measures water vapour (H2O) in air from 0.5 to 32 mg\/L. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from yellowish green to purple, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eWater vapour readings help check moisture in compressed air, process gas and gas dehydration lines. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures water vapour (H2O) from 0.5 to 32 mg\/L\u003c\/li\u003e\u003cli\u003eColour change yellowish green to purple\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e6\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG6\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ewater vapour (H2O)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.5–32 mg\/L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.5–1 mg\/L: 2 strokes (200 mL) in 1.5 min; 1–18 mg\/L: 1 stroke (100 mL) in 45 s; 18–32 mg\/L: ½ stroke (50 mL) in 30 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003eyellowish green to purple\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.1 mg\/L (2 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e10 to 40 °C (50 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eRequired (see the instruction manual)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e6\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/6.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/6.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/6.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568125247702,"sku":"BP-L-IG6","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/6.jpg?v=1791600734"},{"product_id":"gastec-nox-detector-tube-no-11l-0-03-14-ppm-box-of-10-11l","title":"Gastec NOx Detector Tube No. 11L, 0.03–14 ppm, Box of 10","description":"\u003cp\u003eGastec detector tube No. 11L measures nitrogen oxides (NO + NO2) in air from 0.03 to 14 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from white to yellowish orange, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eNitrogen oxides come from combustion, diesel exhaust, welding and cutting, and from some chemical processes. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures nitrogen oxides (NO + NO2) from 0.03 to 14 ppm\u003c\/li\u003e\u003cli\u003eColour change white to yellowish orange\u003c\/li\u003e\u003cli\u003eDirect-reading scale printed on the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e11L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG11L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003enitrogen oxides (NO + NO2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.03–14 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.03–0.06 ppm: 8 strokes (800 mL) in 16 min; 0.06–0.2 ppm: 4 strokes (400 mL) in 8 min; 0.2–5.0 ppm: 2 strokes (200 mL) in 4 min; 5.0–14 ppm: 1 stroke (100 mL) in 2 min\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003ewhite to yellowish orange\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.01 ppm (8 strokes)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e11L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDisposal note\u003c\/th\u003e\u003ctd\u003econtains 2.73 mg of hexavalent chromium per the SDS; dispose of per local regulations\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/11L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/11L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/11L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568125575382,"sku":"BP-L-IG11L","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/11l.jpg?v=1791600784"},{"product_id":"gastec-hydrogen-detector-tube-no-30-0-5-2-box-of-10-30","title":"Gastec Hydrogen Detector Tube No. 30, 0.5–2 %, Box of 10","description":"\u003cp\u003eGastec detector tube No. 30 measures hydrogen (H2) in air from 0.5 to 2 %. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from yellow to yellowish brown, and the stain shows the gas concentration. This is not a direct-reading tube: read the stain length against the concentration chart supplied with the tube. 10 tubes per box give 10 tests.\u003c\/p\u003e\u003cp\u003eHydrogen can collect near battery rooms, charging areas, electrolysis units and process lines. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eMeasures hydrogen (H2) from 0.5 to 2 %\u003c\/li\u003e\u003cli\u003eColour change yellow to yellowish brown\u003c\/li\u003e\u003cli\u003eConcentration chart supplied with the tube\u003c\/li\u003e\u003cli\u003eFor use with a Gastec GV-100 or GV-110 hand pump\u003c\/li\u003e\u003cli\u003e10 tubes per box, 36-month shelf life\u003c\/li\u003e\u003cli\u003eEach production lot is tested and calibrated by the manufacturer\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e30\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IG30\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eColourimetric detector tube\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas measured\u003c\/th\u003e\u003ctd\u003ehydrogen (H2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0.5–2 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003ePump strokes and sampling time\u003c\/th\u003e\u003ctd\u003e0.5–2 %: 1 stroke (100 mL) in 3 min\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour change\u003c\/th\u003e\u003ctd\u003eyellow to yellowish brown\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDetection limit\u003c\/th\u003e\u003ctd\u003e0.5 % (1 stroke)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e0 to 90 %\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTemperature correction\u003c\/th\u003e\u003ctd\u003eNot required\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTubes per box\u003c\/th\u003e\u003ctd\u003e10\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eShelf life\u003c\/th\u003e\u003ctd\u003e36 months\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel No.\u003c\/th\u003e\u003ctd\u003e30\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/sds\/30.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/detector_tube\/30.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification sheet\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/30.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568125608150,"sku":"BP-L-IG30","price":70000.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/30.jpg?v=1791600785"},{"product_id":"gastec-gv-110s-gas-sampling-pump-kit-with-pump-stroke-counter-gv-110s","title":"Gastec GV-110S Gas Sampling Pump Kit with Pump Stroke Counter","description":"\u003cp\u003eThe Gastec GV-110S kit pairs the GV-110 hand-operated gas sampling pump with an automatic pump stroke counter, so you do not have to count strokes yourself. The pump draws a measured air sample (100 mL per full stroke, 50 mL per half stroke) through a Gastec detector tube. The kit comes in a compact case with a shoulder strap.\u003c\/p\u003e\u003cp\u003eThe pump has a built-in diamond-edge tip breaker with a bin for the broken tips, a red leakage indicator on the shaft, and a flow-finish indicator that pops out when the sample is complete. The counter tracks up to ten strokes. The kit includes three rubber tube inlets, lubricant and the instruction manual. Use only Gastec detector tubes with the pump; the tubes are sold separately.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eAutomatic stroke counter tracks up to ten strokes\u003c\/li\u003e\u003cli\u003e100 mL full stroke and 50 mL half stroke, marked on the shaft\u003c\/li\u003e\u003cli\u003eBuilt-in diamond-edge tip breaker with a bin for broken tips\u003c\/li\u003e\u003cli\u003eLeakage indicator and flow-finish indicator\u003c\/li\u003e\u003cli\u003eIncludes 3 rubber inlets, lubricant, instruction manual and carrying case with shoulder strap\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eGastec\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003eGV-110S\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IGV110S\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003eHand-operated gas sampling pump kit\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel\u003c\/th\u003e\u003ctd\u003eGV-110S (pump GV-110)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eSample volume\u003c\/th\u003e\u003ctd\u003e100 mL (full stroke), 50 mL (half stroke)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eStroke counter\u003c\/th\u003e\u003ctd\u003eAutomatic, up to 10 strokes\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eTip breaker\u003c\/th\u003e\u003ctd\u003eBuilt-in, diamond edge\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBody material\u003c\/th\u003e\u003ctd\u003eABS resin and elastomer cover\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eIncluded\u003c\/th\u003e\u003ctd\u003e3 rubber inlets, lubricant, instruction manual, carrying case with shoulder strap\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.gastec.co.jp\/files\/user\/asset\/pdf\/en\/instructionmanual\/en\/GV-100S_GV-110S.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Gastec","offers":[{"title":"Default Title","offer_id":67568125640918,"sku":"BP-L-IGV110S","price":558425.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/gv-110s.jpg?v=1791600785"},{"product_id":"msa-altair-2x-single-gas-detector-carbon-monoxide-co-alarms-25-100-ppm-10153986","title":"MSA ALTAIR 2X Single-Gas Detector, Carbon Monoxide (CO), Alarms 25\/100 ppm","description":"\u003cp\u003eThe MSA ALTAIR 2X is a compact, single-gas portable detector with an electrochemical sensor for carbon monoxide (CO). It shows the reading on a large display and warns the wearer with bright LEDs, a loud audible alarm (95 dB typical at 30 cm) and a vibrating alarm. This version is factory set with a low alarm at 25 ppm and a high alarm at 100 ppm, and it reads 0–1999 ppm.\u003c\/p\u003e\u003cp\u003eCarbon monoxide builds up around engines, generators, heaters and welding or burning work in enclosed spaces. The detector only detects the gas for which its sensor is installed. Check it with a bump test or calibrate it as the manual describes before use, and follow your site procedure for gas testing.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDetects carbon monoxide (CO), 0–1999 ppm\u003c\/li\u003e\u003cli\u003eFactory alarms: low 25 ppm, high 100 ppm\u003c\/li\u003e\u003cli\u003eTwo bright LEDs, 95 dB audible alarm and vibrating alarm\u003c\/li\u003e\u003cli\u003eIP 67 housing, 115 g with battery and clip\u003c\/li\u003e\u003cli\u003eReplaceable non-rechargeable lithium battery\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eMSA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e10153986\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IMSA10153986\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003ePortable single-gas detector, electrochemical sensor\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel\u003c\/th\u003e\u003ctd\u003eALTAIR 2X, CO (25, 100)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas\u003c\/th\u003e\u003ctd\u003ecarbon monoxide (CO)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0–1999 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eResolution\u003c\/th\u003e\u003ctd\u003e1 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eResponse time (t90, typical)\u003c\/th\u003e\u003ctd\u003e\u0026lt;15 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eFactory alarm setpoints\u003c\/th\u003e\u003ctd\u003elow 25 ppm, high 100 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eAlarms\u003c\/th\u003e\u003ctd\u003e2 LEDs, audible 95 dB typical at 30 cm, vibrating\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBattery\u003c\/th\u003e\u003ctd\u003eNon-rechargeable lithium, 3.6 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eWeight\u003c\/th\u003e\u003ctd\u003e115 g (with battery and clip)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDimensions\u003c\/th\u003e\u003ctd\u003e87 x 55 x 48 mm (with clip)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eIngress protection\u003c\/th\u003e\u003ctd\u003eIP 67\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e-10 to 40 °C (normal), -20 to 50 °C (extended)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e15 to 90 %, non-condensing\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour\u003c\/th\u003e\u003ctd\u003eCharcoal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMSA part number\u003c\/th\u003e\u003ctd\u003e10153986\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/docs.msasafety.com\/altair2x\/en-us\/ALTAIR%202X%20INT%20OPM%2010148950\/PDF\/OPM_ALTAIR_2X_10148950_07_US.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"MSA","offers":[{"title":"Default Title","offer_id":67577782304982,"sku":"BP-L-IMSA10153986","price":468425.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/pn-image_10153986.jpg?v=1791668433"},{"product_id":"msa-altair-2x-single-gas-detector-low-concentration-hydrogen-sulfide-h2s-lc-alar","title":"MSA ALTAIR 2X Single-Gas Detector, Low-Concentration Hydrogen Sulfide (H2S-LC), Alarms 5\/10 ppm","description":"\u003cp\u003eThe MSA ALTAIR 2X is a compact, single-gas portable detector with an electrochemical sensor for low-concentration hydrogen sulfide (H2S-LC). It shows the reading on a large display and warns the wearer with bright LEDs, a loud audible alarm (95 dB typical at 30 cm) and a vibrating alarm. This version is factory set with a low alarm at 5 ppm and a high alarm at 10 ppm, and it reads 0–100.0 ppm.\u003c\/p\u003e\u003cp\u003eHydrogen sulfide is found around oil and gas wells, sour gas lines, sewers, ballast and bilge tanks and other confined spaces. The detector only detects the gas for which its sensor is installed. Check it with a bump test or calibrate it as the manual describes before use, and follow your site procedure for gas testing.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDetects low-concentration hydrogen sulfide (H2S-LC), 0–100.0 ppm\u003c\/li\u003e\u003cli\u003eFactory alarms: low 5 ppm, high 10 ppm\u003c\/li\u003e\u003cli\u003eTwo bright LEDs, 95 dB audible alarm and vibrating alarm\u003c\/li\u003e\u003cli\u003eIP 67 housing, 115 g with battery and clip\u003c\/li\u003e\u003cli\u003eReplaceable non-rechargeable lithium battery\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eMSA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e10154076\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IMSA10154076\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003ePortable single-gas detector, electrochemical sensor\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel\u003c\/th\u003e\u003ctd\u003eALTAIR 2X, H2S-LC (5, 10)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas\u003c\/th\u003e\u003ctd\u003elow-concentration hydrogen sulfide (H2S-LC)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0–100.0 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eResolution\u003c\/th\u003e\u003ctd\u003e0.1 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eResponse time (t90, typical)\u003c\/th\u003e\u003ctd\u003e\u0026lt;15 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eFactory alarm setpoints\u003c\/th\u003e\u003ctd\u003elow 5 ppm, high 10 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eAlarms\u003c\/th\u003e\u003ctd\u003e2 LEDs, audible 95 dB typical at 30 cm, vibrating\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBattery\u003c\/th\u003e\u003ctd\u003eNon-rechargeable lithium, 3.6 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eWeight\u003c\/th\u003e\u003ctd\u003e115 g (with battery and clip)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDimensions\u003c\/th\u003e\u003ctd\u003e87 x 55 x 48 mm (with clip)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eIngress protection\u003c\/th\u003e\u003ctd\u003eIP 67\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e-10 to 40 °C (normal), -20 to 50 °C (extended)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e15 to 90 %, non-condensing\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour\u003c\/th\u003e\u003ctd\u003eCharcoal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMSA part number\u003c\/th\u003e\u003ctd\u003e10154076\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/docs.msasafety.com\/altair2x\/en-us\/ALTAIR%202X%20INT%20OPM%2010148950\/PDF\/OPM_ALTAIR_2X_10148950_07_US.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"MSA","offers":[{"title":"Default Title","offer_id":67577782337750,"sku":"BP-L-IMSA10154076","price":468425.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/Atlair-2X.jpg?v=1791668434"},{"product_id":"msa-altair-2x-single-gas-detector-sulfur-dioxide-so2-alarms-2-5-ppm-10154077","title":"MSA ALTAIR 2X Single-Gas Detector, Sulfur Dioxide (SO2), Alarms 2\/5 ppm","description":"\u003cp\u003eThe MSA ALTAIR 2X is a compact, single-gas portable detector with an electrochemical sensor for sulfur dioxide (SO2). It shows the reading on a large display and warns the wearer with bright LEDs, a loud audible alarm (95 dB typical at 30 cm) and a vibrating alarm. This version is factory set with a low alarm at 2 ppm and a high alarm at 5 ppm, and it reads 0–20.0 ppm.\u003c\/p\u003e\u003cp\u003eSulfur dioxide is released when sulfur-bearing fuels and gases are burned, for example at flare stacks, boilers and engine exhaust. The detector only detects the gas for which its sensor is installed. Check it with a bump test or calibrate it as the manual describes before use, and follow your site procedure for gas testing.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDetects sulfur dioxide (SO2), 0–20.0 ppm\u003c\/li\u003e\u003cli\u003eFactory alarms: low 2 ppm, high 5 ppm\u003c\/li\u003e\u003cli\u003eTwo bright LEDs, 95 dB audible alarm and vibrating alarm\u003c\/li\u003e\u003cli\u003eIP 67 housing, 115 g with battery and clip\u003c\/li\u003e\u003cli\u003eReplaceable non-rechargeable lithium battery\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eMSA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e10154077\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IMSA10154077\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003ePortable single-gas detector, electrochemical sensor\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel\u003c\/th\u003e\u003ctd\u003eALTAIR 2X, SO2 (2, 5)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas\u003c\/th\u003e\u003ctd\u003esulfur dioxide (SO2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0–20.0 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eResolution\u003c\/th\u003e\u003ctd\u003e0.1 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eResponse time (t90, typical)\u003c\/th\u003e\u003ctd\u003e\u0026lt;15 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eFactory alarm setpoints\u003c\/th\u003e\u003ctd\u003elow 2 ppm, high 5 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eAlarms\u003c\/th\u003e\u003ctd\u003e2 LEDs, audible 95 dB typical at 30 cm, vibrating\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBattery\u003c\/th\u003e\u003ctd\u003eNon-rechargeable lithium, 3.6 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eWeight\u003c\/th\u003e\u003ctd\u003e115 g (with battery and clip)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDimensions\u003c\/th\u003e\u003ctd\u003e87 x 55 x 48 mm (with clip)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eIngress protection\u003c\/th\u003e\u003ctd\u003eIP 67\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e-10 to 40 °C (normal), -20 to 50 °C (extended)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e15 to 90 %, non-condensing\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour\u003c\/th\u003e\u003ctd\u003eCharcoal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMSA part number\u003c\/th\u003e\u003ctd\u003e10154077\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/docs.msasafety.com\/altair2x\/en-us\/ALTAIR%202X%20INT%20OPM%2010148950\/PDF\/OPM_ALTAIR_2X_10148950_07_US.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"MSA","offers":[{"title":"Default Title","offer_id":67577782370518,"sku":"BP-L-IMSA10154077","price":596125.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/pn-image_10154077.jpg?v=1791668435"},{"product_id":"msa-altair-2x-single-gas-detector-nitrogen-dioxide-no2-alarms-2-5-5-ppm-10154078","title":"MSA ALTAIR 2X Single-Gas Detector, Nitrogen Dioxide (NO2), Alarms 2.5\/5 ppm","description":"\u003cp\u003eThe MSA ALTAIR 2X is a compact, single-gas portable detector with an electrochemical sensor for nitrogen dioxide (NO2). It shows the reading on a large display and warns the wearer with bright LEDs, a loud audible alarm (95 dB typical at 30 cm) and a vibrating alarm. This version is factory set with a low alarm at 2.5 ppm and a high alarm at 5 ppm, and it reads 0–50.0 ppm.\u003c\/p\u003e\u003cp\u003eNitrogen dioxide comes from combustion, diesel exhaust, welding and cutting, and some chemical processes. The detector only detects the gas for which its sensor is installed. Check it with a bump test or calibrate it as the manual describes before use, and follow your site procedure for gas testing.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eDetects nitrogen dioxide (NO2), 0–50.0 ppm\u003c\/li\u003e\u003cli\u003eFactory alarms: low 2.5 ppm, high 5 ppm\u003c\/li\u003e\u003cli\u003eTwo bright LEDs, 95 dB audible alarm and vibrating alarm\u003c\/li\u003e\u003cli\u003eIP 67 housing, 115 g with battery and clip\u003c\/li\u003e\u003cli\u003eReplaceable non-rechargeable lithium battery\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003cth\u003eBrand\u003c\/th\u003e\u003ctd\u003eMSA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eManufacturer part number (MPN)\u003c\/th\u003e\u003ctd\u003e10154078\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBig Papa SKU\u003c\/th\u003e\u003ctd\u003eBP-L-IMSA10154078\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eType\u003c\/th\u003e\u003ctd\u003ePortable single-gas detector, electrochemical sensor\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eModel\u003c\/th\u003e\u003ctd\u003eALTAIR 2X, NO2 (2.5, 5)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eGas\u003c\/th\u003e\u003ctd\u003enitrogen dioxide (NO2)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMeasuring range\u003c\/th\u003e\u003ctd\u003e0–50.0 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eResolution\u003c\/th\u003e\u003ctd\u003e0.1 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eResponse time (t90, typical)\u003c\/th\u003e\u003ctd\u003e\u0026lt;15 s\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eFactory alarm setpoints\u003c\/th\u003e\u003ctd\u003elow 2.5 ppm, high 5 ppm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eAlarms\u003c\/th\u003e\u003ctd\u003e2 LEDs, audible 95 dB typical at 30 cm, vibrating\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eBattery\u003c\/th\u003e\u003ctd\u003eNon-rechargeable lithium, 3.6 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eWeight\u003c\/th\u003e\u003ctd\u003e115 g (with battery and clip)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eDimensions\u003c\/th\u003e\u003ctd\u003e87 x 55 x 48 mm (with clip)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eIngress protection\u003c\/th\u003e\u003ctd\u003eIP 67\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eOperating temperature\u003c\/th\u003e\u003ctd\u003e-10 to 40 °C (normal), -20 to 50 °C (extended)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eRelative humidity\u003c\/th\u003e\u003ctd\u003e15 to 90 %, non-condensing\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eColour\u003c\/th\u003e\u003ctd\u003eCharcoal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003cth\u003eMSA part number\u003c\/th\u003e\u003ctd\u003e10154078\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/docs.msasafety.com\/altair2x\/en-us\/ALTAIR%202X%20INT%20OPM%2010148950\/PDF\/OPM_ALTAIR_2X_10148950_07_US.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUser instructions\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"MSA","offers":[{"title":"Default Title","offer_id":67577785647318,"sku":"BP-L-IMSA10154078","price":596125.0,"currency_code":"XOF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/files\/pn-image_10154078.jpg?v=1791668468"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/8595\/3494\/collections\/gas-detection_65f9d3bd-7a8c-4de9-b2df-f8a0c1545f9c.png?v=1766103613","url":"https:\/\/bigpapaentreprise.com\/en-us\/collections\/gas-detection.oembed?page=2","provider":"Big Papa Enterprise Ltd","version":"1.0","type":"link"}