Description
Gastec detector tube No. 5LC measures sulfur dioxide (SO2) in air from 0.1 to 22 ppm. Break both tips off the tube, fit it to a Gastec GV-100 or GV-110 hand pump and draw the number of pump strokes listed for the expected range. The reagent changes from bluish purple to white, and the stain shows the gas concentration. Read the concentration directly on the scale printed on the tube. 10 tubes per box give 10 tests.
Sulfur dioxide is released when sulfur-bearing fuels and gases are burned, for example at flare stacks, boilers and engine exhaust. A tube gives a spot reading and does not replace a certified gas monitor where your site procedure requires one. Use only Gastec tubes with a Gastec pump, break the tips away from your eyes, and never handle broken glass or reagent with bare hands.
Features
- Measures sulfur dioxide (SO2) from 0.1 to 22 ppm
- Colour change bluish purple to white
- Direct-reading scale printed on the tube
- For use with a Gastec GV-100 or GV-110 hand pump
- 10 tubes per box, 36-month shelf life
- Each production lot is tested and calibrated by the manufacturer
Specifications
| Brand | Gastec |
|---|---|
| Manufacturer part number (MPN) | 5LC |
| Big Papa SKU | BP-L-IG5LC |
| Type | Colourimetric detector tube |
| Gas measured | sulfur dioxide (SO2) |
| Measuring range | 0.1–22 ppm |
| Pump strokes and sampling time | 0.1–0.25 ppm: 4 strokes (400 mL) in 8 min; 0.25–10 ppm: 2 strokes (200 mL) in 4 min; 10–22 ppm: 1 stroke (100 mL) in 2 min |
| Colour change | bluish purple to white |
| Detection limit | 0.02 ppm (4 strokes) |
| Operating temperature | 0 to 40 °C (32 to 104 °F) |
| Relative humidity | 0 to 90 % |
| Temperature correction | Required (see the instruction manual) |
| Tubes per box | 10 |
| Shelf life | 36 months |
| Model No. | 5LC |